Membrane Type: Spiral
Type: RO
Stable Salt Rejection: 99.7%
Gpd: 11000gallon/Day
Usage: RO Water Treatment System
Core Technology: Thin Film Nanocomposite
Samples:
US$ 320.26/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Jiangsu, China
Self-branded
The supplier has 17 Self-brands, check the Audit Report for more information
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 12 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (23)
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Sucessful Application
  • Certifications
  • Packaging & Shipping
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
Pro-FR-8040F34
Warranty
12months
Capacity
5000PCS/Month
Delivery Time
10-15 Days
Feature
Anti-Fouling, Large Flux, Durability
Transport Package
Carton Box
Specification
8 Inch
Trademark
Proshare
Origin
China
HS Code
8421999090

Product Description

Product Description
 
RO Membrane Element for Stable Salt Rejection

A common problem with RO membrane elements is fouling.
Fouling does not change the structure of RO membrane elements,but the foulant on the membrane surface can significantly reduce its performance.
Proshare Anti- Fouling reverse osmosis (RO) prevents fouling by applying a exclusive hydrophilic coating on the membrane surface, enabling long-term stable operation. By preventing fouling, reduced cleaning frequency eventually contributes to lower OPEX at the water treatment plant.Proshare Anti- Fouling fits your demand of treating urban sewage water for industrial application.
Key feature:

1.Reduce the cleaning frequency of chemicals and drug amounts, extend long service time of membrane elements.
2. Energy savings up to 30% while the same water flow rate .
3. The widest pH range greatly limiting the growth of microorganisms.
Key applications:

Softening,producing pure water and water reuse in
pharmaceutic,electronics,power,petrochemical,refinery,food&beverage,municipal.etc.

RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
Large Flux Performance of Proshare Pro-FR            Membrane Performance( Proshare VS T** )                             Analysis of RO Trouble at Site
Product Parameters
 
Product Effective Membrane  area
   ft² (m²)
Feed spacer thickness  (mil) Product Flow Rate ¹ 
    ²g p d( m ³/d)
Stable Salt Rejection¹
    (%)
Pro-FR-4040F34³ 82(7.6) 34 2400(9.1) 99.7
Pro-FR-8040F34³ 400(37) 34 11000(41.6) 99.7
 

1. The product flow rate and salt rejection rate are determined under the following meticulously controlled test conditions:
Feed water concentration: 2000 ppm as NaCl, Feed water pressure: 225 psi (1.55 MPa), Feed water temperature: 77 °F (25 °C), Recovery rate: 15%.
2. The product flow variation range is within +/-15%, ensuring consistent performance.
3. The F34 model features a robust fiberglass-wrapped case with a mesh thickness of 34 mil. Additional case types, meshes, and membrane elements are also available to meet various specifications.

Operating Conditions:

Operating Limits Unit Value
Maximum operatingpressure psi(MPa) 600(41)
Maximumfeed water temperature °F(°C) 113(45)
Maximum pressure drop bar 1
ContinuousoperationpH range   2~11
Cleaning PH range   1~13
Maximum feed watere SDl15   5
Maximum influent turbidity ntu 1
Maximum residual chlorine concentration of influent ppm <0.1
 
SIZE: mm
Model A B C
4040 1016 100.3 19.1
8040 1016 200 28.6
RO Membrane Element for Stable Salt Rejection
             
Our Advantages

RO Membrane Element for Stable Salt RejectionRO Membrane Element for Stable Salt RejectionRO Membrane Element for Stable Salt RejectionRO Membrane Element for Stable Salt Rejection
Sucessful Application
 
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
 

Seawater Desalination Achieve                      Zero Discharge in Latex Wastewater                Advanced Treatment for Copper Foil Industry Wastewater
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
 
New Energy Industry Solution                        Purification and Recovery of Sulfuric Acid                    Efficient Extraction of Lithium from Salt Lake
Certifications
 
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
 
Health & Safety Management System Certificate, Environmental Management System Certificate, ISO 9001 Quality System Certificate
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
 
Invention Patent for Membrane Production, Invention Patent for Multi-Layer RO Membrane, Utility Model Patent Certificates
Packaging & Shipping
 
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
RO Membrane Element for Stable Salt Rejection
 
FAQ
 

1. Q: Are you a manufacturer or a trading company?
A:We are a manufacturer with our own factory. Additionally, we collaborate with other factories utilizing our proprietary technology.
2. Q: What is the lead time for mass production?
A: Our production time for regular models is 10-15 days.
3. Q: How do you guarantee product quality?
A: We meticulously inspect and control every step of the process, from raw materials to production, finished products, and shipping.
4. Q: Can you offer samples before a mass order? Are they free or extra?
A: Yes, we will kindly arrange samples for your confirmation. Please contact us for more details.
5. Q: Why choose us?
We leverage advanced technology for the production of TFN membranes.
We have established China's first TFN coating production line, achieving stable mass production.
We have a 1000m2 test platform equipped with advanced water testing technology.
We provide RO, NF,UNF, Special Membrane Elements, and SPEC Customized Membranes.
We offer our customers competitive prices, excellent product quality, and comprehensive services.

Company Profile

RO Membrane Element for Stable Salt Rejection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now